RYMQ-T

RYMQ18T7Y1BRYMQ20T7Y1B
Cooling capacityNom.kW50.0 (1)56.0 (1)
Heating capacityNom.kW56.0 (2)63.0 (2)
Power input – 50HzCoolingNom.kW14.7 (1)18.5 (1)
HeatingNom.kW14.4 (2)17.0 (2)
EER3.40 (1)3.03 (1)
COP3.89 (2)3.71 (2)
Capacity rangeHP1820
Maximum number of connectable indoor units64 (3)64 (3)
Indoor index connectionMin.225250
Nom.450500
Max.585650
DimensionsUnitHeightmm1,6851,685
Widthmm1,2401,240
Depthmm765765
WeightUnitkg319319
FanAir flow rateCoolingNom.m³/min251261
External static pressureMax.Pa7878
CompressorTypeHermetically sealed scroll compressorHermetically sealed scroll compressor
Operation rangeCoolingMax.°CDB4343
HeatingMin.°CWB-20-20
Max.°CWB15.515.5
Sound power levelCoolingNom.dBA8688
Sound pressure levelCoolingNom.dBA6566
RefrigerantTypeR-410AR-410A
Piping connectionsLiquidTypeBraze connectionBraze connection
ODmm15.915.9
GasTypeBraze connectionBraze connection
ODmm28.628.6
Oil equalizingTypeBraze connectionBraze connection
ODmm28.628.6
Heat insulationLiquid, gas and equalizing pipeLiquid, gas and equalizing pipe
Total piping lengthSystemActualm1,000 (7)1,000 (7)
Level differenceOU – IUOutdoor unit in highest positionm90 (7)90 (7)
Indoor unit in highest positionm90 (7)90 (7)
IU – IUMax.m30 (7)30 (7)
Standard AccessoriesItemInstallation and operation manualInstallation and operation manual
ItemConnection pipesConnection pipes
Power supplyNameY1Y1
Phase3N~3N~
FrequencyHz5050
VoltageV380-415380-415
NotesCooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); level difference: 0mCooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (horizontal); level difference: 0m
Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0mHeating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
Actual number of connectable indoor units depends on the indoor unit type (VRV indoor, Hydrobox, RA indoor, etc.) and the connection ratio restriction for the system (50%Actual number of connectable indoor units depends on the indoor unit type (VRV indoor, Hydrobox, RA indoor, etc.) and the connection ratio restriction for the system (50%
For more details on operation range see TW drawingFor more details on operation range see TW drawing
Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
Maximum allowable voltage range variation between phases is 2%.Maximum allowable voltage range variation between phases is 2%.
Refer to refrigerant pipe selection or installation manualRefer to refrigerant pipe selection or installation manual
For more details on standard accessories refer to Installation/operation manualFor more details on standard accessories refer to Installation/operation manual
RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDBRLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB
MSC means the maximum current during start up of the compressor. VRV IV uses only inverter compressors. Starting current is always ≤ max. running current.MSC means the maximum current during start up of the compressor. VRV IV uses only inverter compressors. Starting current is always ≤ max. running current.
Select wire size based on the value of MCA. The MCA can be regarded as the maximum running current.Select wire size based on the value of MCA. The MCA can be regarded as the maximum running current.
MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker).MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker).
TOCA means the total value of each OC set.TOCA means the total value of each OC set.
FLA means the nominal running current of the fanFLA means the nominal running current of the fan
Sound power level is an absolute value that a sound source generates.Sound power level is an absolute value that a sound source generates.
Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings.Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings.
Sound values are measured in a semi-anechoic room.Sound values are measured in a semi-anechoic room.